CHTD Dry-installed pump

Dry-installed pump CHTD

Horizontal high-pressure barrel-type pumps with radial impellers, single-entry and double-entry, multistage, with flanges or weld end nozzles to DIN and ANSI.
See all documents and downloads

Main Applications

  • Pumping boiler feed water and condensate in power stations and industrial plants
  • Generation of pressurised water for descaling units

Technical Data

Maximum flow rate TSG
5700 m3/h
Maximum head TSG
5400 m
Max allow ds work.pressure TSG
560 bar
Max allowed fluid temp TSG
270 °C

Your KSB contact: We’re here to support you

Do you need any assistance finding the right material number?
We’ll soon provide a list so you can directly place your purchase order.
Meanwhile please contact our support:

Your local contact


Your KSB contact : We’re here to support you

Benefits

  • High operating reliability:
    • For balancing by double drum: residual axial thrust absorbed by pivoted segmental thrust bearing
    • Optimised casing design regarding the distribution of forces

Technical Data

Component function
Pump
Connection type Inlet
Flange,
Butt weld ends
Drive concept
With electric actuator,
Turbine
Maximum flow rate TSG
5700 m3/h
Minimum flow rate TSG
0.1 m3/h
Maximum head TSG
5400 m
Minimum head TSG
0.1 m
Mains frequency
50 Hz,
60 Hz
Mains voltage
400 V,
415 V,
440 V,
460 V,
480 V,
500 V,
525 V,
575 V,
600 V,
660 V,
690 V,
760 V,
830 V,
1000 V,
3000 V,
4160 V,
5000 V,
5500 V,
6000 V,
6600 V,
6900 V,
11000 V
Max allow ds work.pressure TSG
560 bar
Suction behaviour
Non-self-priming
Max allowed fluid temp TSG
270 °C
Min allowed fluid temp TSG
2 °C