Main Applications
- Feed water in power stations
- Pumping condensate in power stations and industrial plants
- Boiler feed booster pump in systems with low suction head
Technical Data
- Maximum flow rate TSG
- 3700 m3/h
- Maximum head TSG
- 250 m
- Max allow ds work.pressure TSG
- 40 bar
- Max allowed fluid temp TSG
- 210 °C
Benefits
- High availability and long service life
- Radial forces minimised by double volute casing
- Higher efficiency
Technical Data
- Component function
- Pump
- Connection type Inlet
- Flange,
Butt weld ends - Drive concept
- With electric actuator
- Maximum flow rate TSG
- 3700 m3/h
- Minimum flow rate TSG
- 150 m3/h
- Maximum head TSG
- 250 m
- Minimum head TSG
- 30 m
- Mains frequency
- 50 Hz,
60 Hz - Mains voltage
- 400 V,
460 V - Mtrl Hydraulic casing
- GP240GH+QT KTA
- Nominal pressure Outlet
- PN 40
- Max allow ds work.pressure TSG
- 40 bar
- Suction behaviour
- Non-self-priming
- Max allowed fluid temp TSG
- 210 °C
- Min allowed fluid temp TSG
- 2 °C