YNK Dry-installed pump

Dry-installed pump YNK

Horizontal radially split single-stage double-entry boiler feed booster pump (booster system) with cast steel single or double volute casing.
See all documents and downloads

Main Applications

  • Feed water in power stations
  • Pumping condensate in power stations and industrial plants
  • Boiler feed booster pump in systems with low suction head

Technical Data

Maximum flow rate TSG
3700 m3/h
Maximum head TSG
250 m
Max allow ds work.pressure TSG
40 bar
Max allowed fluid temp TSG
210 °C

Your KSB contact: We’re here to support you

Do you need any assistance finding the right material number?
We’ll soon provide a list so you can directly place your purchase order.
Meanwhile please contact our support:

Your local contact


Your KSB contact : We’re here to support you

Benefits

  • High availability and long service life
  • Radial forces minimised by double volute casing
  • Higher efficiency

Technical Data

Component function
Pump
Connection type Inlet
Flange,
Butt weld ends
Drive concept
With electric actuator
Maximum flow rate TSG
3700 m3/h
Minimum flow rate TSG
150 m3/h
Maximum head TSG
250 m
Minimum head TSG
30 m
Mains frequency
50 Hz,
60 Hz
Mains voltage
400 V,
460 V
Mtrl Hydraulic casing
GP240GH+QT KTA
Nominal pressure Outlet
PN 40
Max allow ds work.pressure TSG
40 bar
Suction behaviour
Non-self-priming
Max allowed fluid temp TSG
210 °C
Min allowed fluid temp TSG
2 °C