MIL 76000 Globe valve

Globe valve MIL 76000

The letdown control valves in angle pattern are designed for all applications where flashing (flash evaporation) or two-phase (liquid and gaseous) flows may occur; no body/trim erosion, vibration or noise. Due to its angle pattern, the globe valve is self-draining.
See all documents and downloads

Technical Data

Nominal pressure
CL 150, CL 300, CL 600, CL 900, CL 1500, CL 2500
Max. nominal size
NPS 2
Maximum allowable fluid temperature
566 °C

Your KSB contact: We’re here to support you

Do you need any assistance finding the right material number?
We’ll soon provide a list so you can directly place your purchase order.
Meanwhile please contact our support:

Tel: +32 -10 435 211


Your KSB contact : We’re here to support you

Technical Data

Function
Shut off/control flow
Design concept Drive
With electric actuator,
Hydraulic,
With pneumatic actuator
Nominal pressure
CL 150,
CL 300,
CL 600,
CL 900,
CL 1500,
CL 2500
Max. nominal size
NPS 2
Min. nominal size
NPS 1
Maximum allowable fluid temperature
566 °C
Minimum allowable fluid temperature
-27 °C