Sprinkler pumps

KSB's sprinkler pumps and pump sets provide safety when things get hot.

Insurers of fire protection systems only trust products that meet the requirements on design, certification, production, documentation and marking 100 %. For a good reason. The dimensions are specified in the applicable fire protection directives. Here you will find an overview of all suitable KSB products for the corresponding directives.

Sprinkler pumps and pump sets to national and international fire protection directives

pic-Brandschutzrichtlinien

tea-pic-Brandschutzrichtlinien

The following design variants are available from KSB:

pic-Einzelnes Pumpenaggregat

Single pump set

pic-Elektropumpenaggregat

Electric motor pump set with wired control cabinet on a common base frame

pic-Dieselpumpenaggregat

Diesel engine pump set with tank, control cabinet and batteries

Sprinkler pumps and sprinkler pump sets to VdS

We offer sprinkler pump sets compliant with the VdS guideline in a large range of different design variants, certainly also matching your application: As a submersible motor pump installed in the sprinkler tank with a control cabinet in the sprinkler control room or as a dry-installed pump set for installation in the sprinkler control room.

Sprinkler pump sets designed as submersible pumps

Dry-installed sprinkler pump sets

Dry-installed sprinkler pump sets

Sprinkler pump sets designed as submersible pumps

 UPAVdS MovitecEtanorm FXVEtanorm RXCPKN-SXMultitec ASX
l/min max at VdS approval limit68701033134661566779493000
H (m) max at VdS approval limit17316610774119550
Drive typesElectric motorElectric motor or diesel engine
Place of installationIn the sprinkler tankIn the sprinkler control room

 

Sprinkler pumps and pump sets to FM, UL or NFPA 20

Our FM, UL or NFPA 20 product range comprises the Etanorm FXM and Omega FXF type series. The pump sets are available driven by an electric motor or diesel engine.


Available KSB sprinkler pumps approved by FM or UL:

Etanorm FXMOmega FXF 

Q rated max (US Gpm)

1500

3500

H (m) max at Q rated

137

120

Possible drive typeElectric motor and diesel engine

Sprinkler pumps and pump sets to APSAD R1, EN 12845 or without certification / listing

In many countries, additional fire protection directives are in force. Here, too, our KSB sprinkler pumps cover a broad range. 

Jockey pumps or tank filling pumps for sprinkler installations

To make sure that the main fire-fighting pumps do not start up automatically when minor leakage losses occur in the sprinkler system, these pumps maintain a defined pressure in the sprinkler system and balance out water losses. They do not need to comply with national or international fire protection guidelines.