Sturdy rotary lobe pump in hygienic design, bi-directional operation possible, horizontal or vertical orientation of connections. Hygienic design, excellent CIP/SIP compatibility due to its almost complete lack of dead volume or narrow clearances. All wetted components made of 1.4404/1.4409 (AISI 316L/CF3M) stainless steel; various rotor types, shaft seals and process connections available. Installed as a pump set with gear unit and standardised motor. Vitalobe is EHEDG-certified. The pump elastomers comply with the FDA standards and EN 1935/2004. Accessories include a trolley, a heatable casing or casing cover and a pressure relief arrangement. ATEX-compliant version available.
Lihat semua dokumen dan unduhan

Aplikasi utama

  • Food industry / beverage industry
  • Pharmaceutical industry
  • Cosmetics industry
  • General industry

Data teknis

Maximum flow rate TSG
300 m3/h
Maximum head TSG
150 m
Max allow ds work.pressure TSG
20 bar
Max allowed fluid temp TSG
160 °C

Your KSB contact: We’re here to support you

Do you need any assistance finding the right material number?
We’ll soon provide a list so you can directly place your purchase order.
Meanwhile please contact our support:

Your local contact


Kontak KSB: Kami ada untuk Anda

Manfaat

  • Hygienic zero dead volume design for residue-free and fast CIP/SIP
  • Flexible with horizontal in-line or vertical in-line connections
  • Flexible with different types and materials of rotary lobes, matched to the specific application

Sertifikat

  • V06A_19598661387-1_1
    Certified quality management to ISO 9001
    All countries
  • V06A_19598661387-3_1
    Elastomers certified to FDA, 3A, USP Class VI
    All countries
  • V06A_19598661387-2_1
    European Hygienic Engineering & Design Group
    All countries

Data teknis

Component function
Pump
Connection type Inlet
External-thread connection,
Flange
Drive concept
With electric actuator
Maximum flow rate TSG
300 m3/h
Minimum flow rate TSG
0.1 m3/h
Maximum head TSG
150 m
Minimum head TSG
0.1 m
Mains frequency
50 Hz,
60 Hz
Mains voltage
400 V
Mtrl Hydraulic casing
GX2CRNIMO19-11-2
Nominal pressure Outlet
PN 20
Max allow ds work.pressure TSG
20 bar
Suction behaviour
Non-self-priming
Max allowed fluid temp TSG
160 °C
Min allowed fluid temp TSG
-40 °C