MegaCPK Dry-installed pump

Dry-installed pump MegaCPK

Horizontal radially split volute casing pump in back pull-out design, with radial impeller, single-entry, single-stage, to DIN EN ISO 5199, dimensions to DIN EN ISO 2858, complemented by nominal diameters DN25 and ≥DN200, in large range of material and seal variants; also available as a variant with "wet" shaft and conical seal chamber. ATEX-compliant version available.
Lihat semua dokumen dan unduhan

Aplikasi utama

  • Chemical industry (aggressive / other liquids)
  • Petrochemical industry (aggressive / other liquids)
  • Process engineering
  • Refinery

Data teknis

Maximum flow rate TSG
3300 m3/h
Maximum head TSG
162 m
Max allow ds work.pressure TSG
25 bar
Max allowed fluid temp TSG
400 °C

Your KSB contact: We’re here to support you

Do you need any assistance finding the right material number?
We’ll soon provide a list so you can directly place your purchase order.
Meanwhile please contact our support:

Your local contact


Kontak KSB: Kami ada untuk Anda

Manfaat

  • Hydraulic characteristics optimised for excellent efficiency and NPSH, ensuring energy-efficient and environmentally friendly use of resources
  • Lower investment costs as duty points required can be achieved with smaller pump sizes
  • Lower operating costs due to reduced energy consumption, optimised spare parts concept and hard-wearing, service-friendly design

Data teknis

Component function
Pump
Connection type Inlet
Flange
Drive concept
With electric actuator
Maximum flow rate TSG
3300 m3/h
Minimum flow rate TSG
2 m3/h
Maximum head TSG
162 m
Minimum head TSG
2 m
Mains frequency
50 Hz,
60 Hz
Mtrl Hydraulic casing
EN-GJL-250/A48 CL 35B,
GP240GH+N/A216 GR WCB,
G17CRMOV5-10,
GX5CRNIMO19-11-2/A743 GR CF-8M,
GX3CRNIMOCUN24-6-2-3/GX2CRNIMOCUN25-6-3-3/A9951B
Nominal pressure Outlet
PN 25
Max allow ds work.pressure TSG
25 bar
Suction behaviour
Non-self-priming
Max allowed fluid temp TSG
400 °C
Min allowed fluid temp TSG
-40 °C

Gambar penampang