Etanorm Dry-installed pump

Dry-installed pump Etanorm

Horizontal volute casing pump, single-stage, with ratings and main dimensions to EN 733, long-coupled, back pull-out design, with replaceable shaft sleeves / shaft protecting sleeves and casing wear rings, with motor-mounted variable speed system. With KSB SuPremE, a magnetless synchronous reluctance motor (exception: motor sizes 0.55 kW / 0.75 kW with 1500 rpm are designed with permanent magnets) of efficiency class IE4/IE5 to IEC TS 60034-30-2:2016, for operation on a KSB PumpDrive 2 or KSB PumpDrive 2 Eco variable speed system without rotor position sensors. Motor mounting points in accordance with EN 50347, envelope dimensions in accordance with DIN V 42673 (07-2011). ATEX-compliant version available.
Lihat semua dokumen dan unduhan

Aplikasi utama

  • Handling clean or aggressive fluids not chemically and mechanically aggressive to the pump materials.
  • Water supply systems
  • Cooling circuits
  • Swimming pools

Data teknis

Maximum flow rate TSG
1368 m3/h
Maximum head TSG
160 m
Max allow ds work.pressure TSG
16 bar
Max allowed fluid temp TSG
140 °C

Your KSB contact: We’re here to support you

Do you need any assistance finding the right material number?
We’ll soon provide a list so you can directly place your purchase order.
Meanwhile please contact our support:

Your local contact


Kontak KSB: Kami ada untuk Anda

Manfaat

  • Improved efficiency and NPSHreq by experimentally verified hydraulic design of impellers (vanes)
  • Operating costs reduced by trimming the nominal impeller diameter to match the specified duty point
  • Little wear, low vibration levels and excellent smooth running characteristics thanks to good suction performance and virtually cavitation-free operation across a wide operating range

Data teknis

Component function
Pump
Connection type Inlet
Flange
Drive concept
With electric actuator,
Combustion engine
Maximum flow rate TSG
1368 m3/h
Minimum flow rate TSG
1.5 m3/h
Maximum head TSG
160 m
Minimum head TSG
2 m
Mains frequency
50 Hz,
60 Hz
Mains voltage
400 V,
460 V,
220 V,
230 V,
240 V,
380 V,
415 V,
500 V,
575 V,
660 V,
690 V
Mtrl Hydraulic casing
EN-GJL-250/A48 CL 35B,
CC480K-GS/B30 C90700,
1.4408/A743CF8M,
EN-GJS-400-15/A536 GR 60-40-18
Nominal pressure Outlet
PN 16,
PN 10,
CL 150,
CL 125
Max allow ds work.pressure TSG
16 bar
Suction behaviour
Non-self-priming
Max allowed fluid temp TSG
140 °C
Min allowed fluid temp TSG
-30 °C

Gambar penampang