Magnochem Dry-installed pump

Dry-installed pump Magnochem

Horizontal seal-less volute casing pump in back pull-out design, with magnetic drive, to DIN EN ISO 2858 / ISO 5199, with radial impeller, single-entry, single-stage. ATEX-compliant version available.
See all documents and downloads

Main Applications

  • Chemical industry
  • District heating
  • Industrial recirculation systems
  • Air-conditioning systems

Technical Data

Max. flow rate
1400 m3/h
Max. head
236 m
Max. allowed working pressure
40 bar
Maximum allowable fluid temperature
350 °C
Magnochem: the standardised chemical mag-drive pump with a proven track record  - now available for hotter fluids and even safer

The proven mag-drive pump to ISO 2858 and ISO 5199 is particularly suitable for handling toxic, explosive or valuable liquids in the chemical, petrochemical or general industries. With its ATEX approval, Magnochem ensures maximum operating reliability along with maximum efficiency and zero leakage.

Would you like further information? Watch our brief product video:

MagnoProtect-vvb

The mag-drive pumps of the Magnochem type series meet the particularly high requirements of the chemical and petrochemical industries.

KSB’s newly developed MagnoProtect containment shroud raises the safety level of Magnochem even further. At the same time, it ensures energy-efficient operation.
Would you like more information?

Take a look at our short product video

Your KSB contact: We're here to support you

Do you need any assistance finding the right material number?
We’ll soon provide a list so you can directly place your purchase order.
Meanwhile please contact our support:

Tel: +33 9 69 39 29 79


Your KSB contact : We’re here to support you

Technical Data

Function
Pump
Connection type
Flange
Drive concept
With electric actuator
Max. flow rate
1400 m3/h
Min. flow rate
1 m3/h
Max. head
236 m
Min. head
3.5 m
Mains frequency
50 Hz,
60 Hz
Mains voltage
400 V,
460 V
Casing material
GP240GH+N/A216 GR WCB,
G17CRMOV5-10,
GX5CRNIMO19-11-2/A743 GR CF-8M,
GX5CRNIMO19-11-2,
GX3CRNIMOCUN24-6-2-3/GX2CRNIMOCUN25-6-3-3/A9951B
Nominal pressure
PN 40
Max. allowed working pressure
40 bar
Suction behaviour
Non-self-priming
Maximum allowable fluid temperature
350 °C
Minimum allowable fluid temperature
-90 °C

Sectional Drawings