Etanorm Dry-installed pump

Dry-installed pump Etanorm

Horizontal volute casing pump, single-stage, with ratings and main dimensions to EN 733, long-coupled, back pull-out design, with replaceable shaft sleeves / shaft protecting sleeves and casing wear rings, with motor-mounted variable speed system. With KSB SuPremE, a magnetless synchronous reluctance motor (exception: motor sizes 0.55 kW / 0.75 kW with 1500 rpm are designed with permanent magnets) of efficiency class IE4/IE5 to IEC TS 60034-30-2:2016, for operation on a KSB PumpDrive 2 or KSB PumpDrive 2 Eco variable speed system without rotor position sensors. Motor mounting points in accordance with EN 50347, envelope dimensions in accordance with DIN V 42673 (07-2011). ATEX-compliant version available.
See all documents and downloads

Main Applications

  • Handling clean or aggressive fluids not chemically and mechanically aggressive to the pump materials.
  • Water supply systems
  • Cooling circuits
  • Swimming pools

Technical Data

Max. flow rate
1368 m3/h
Max. head
160 m
Max. allowed working pressure
16 bar
Maximum allowable fluid temperature
140 °C

Material number list – Etanorm

5,439 products
Material number
Price
ETN 040-025-160-GBSAA10GSEBS2AHBKSB Etanorm [B]40-25-160GBCode 10169mmDN 40DN 25Without0.3without32.73 kg48282518
Loading...
ETN 040-025-160-GBSL11AGSEBS2AHBKSB Etanorm [B]40-25-160GBCode 1A169mmDN 40DN 25Without0.3without34.06 kg48282519
Loading...
ETN 040-025-160-GGSAA10GSEAP1EABKSB Etanorm [B]40-25-160GGCode 10169mmDN 40DN 25Frequency inverterThree-phase current400V0.55kW0.7KSB PumpDrive2 [A]94.52 kg05122211
Loading...
ETN 040-025-160-GGSAA10GSEAP1EABKSB Etanorm [B]40-25-160GGCode 10169mmDN 40DN 25Frequency inverterThree-phase current400V0.55kW0.7KSB PumpDrive2 [A]94.52 kg05122055
Loading...
ETN 040-025-160-GGSAA10GSEAP1EABKSB Etanorm [B]40-25-160GGCode 10169mmDN 40DN 25Frequency inverterThree-phase current400V0.55kW0.7KSB PumpDrive2 [A]89.35 kg05121789
Loading...

Benefits

  • Improved efficiency and NPSHreq by experimentally verified hydraulic design of impellers (vanes)
  • Operating costs reduced by trimming the nominal impeller diameter to match the specified duty point
  • Little wear, low vibration levels and excellent smooth running characteristics thanks to good suction performance and virtually cavitation-free operation across a wide operating range

Technical Data

Function
Pump
Connection type
Flange
Drive concept
With electric actuator,
Combustion engine
Max. flow rate
1368 m3/h
Min. flow rate
1.5 m3/h
Max. head
160 m
Min. head
2 m
Mains frequency
50 Hz,
60 Hz
Mains voltage
400 V,
460 V,
220 V,
230 V,
240 V,
380 V,
415 V,
500 V,
575 V,
660 V,
690 V
Casing material
EN-GJL-250/A48 CL 35B,
CUSN10-C-GS/B30 C90700,
GX5CRNIMO19-11-2/A743 GR CF-8M,
EN-GJS-400-15/A536 GR 60-40-18
Nominal pressure
PN 16,
PN 10,
CL 150,
CL 125
Max. allowed working pressure
16 bar
Suction behaviour
Non-self-priming
Maximum allowable fluid temperature
140 °C
Minimum allowable fluid temperature
-30 °C

Sectional Drawings