UPA C 150 Submersible borehole pump

Submersible borehole pump UPA C 150

All-stainless steel single-stage or multistage centrifugal pump in ring-section design, suitable for vertical or horizontal installation, for well diameters of 150 mm (6 inches) and above.
See all documents and downloads

Main Applications

  • Spray irrigation systems
  • General irrigation systems
  • Pressure boosting
  • Lowering groundwater levels

Technical Data

Max. flow rate
80 m3/h
Max. head
420 m
Max. allowed working pressure
60 bar
Maximum allowable fluid temperature
50 °C

Your KSB contact: We’re here to support you

Do you need any assistance finding the right material number?
We’ll soon provide a list so you can directly place your purchase order.
Meanwhile please contact our support:

Tel: +86 4000218000


Your KSB contact : We’re here to support you

Benefits

  • High operating reliability and long service life due to reinforced suction strainer, robust drive lantern and lift check valve made of investment cast stainless steel, laser-welded impellers and protection against thrust reversal
  • High operating reliability as all components are made of high-quality stainless steel.
  • High efficiencies through optimised hydraulic design

Certificates

  • U16A_5569654667-2_1
    Approved in accordance with the French drinking water regulation
    France
  • U16A_5569654667-1_1
    Certified quality management to ISO 9001
    All countries

Technical Data

Function
Pump
Connection type
Internal-thread connection,
Flange
Drive concept
With electric actuator
Max. flow rate
80 m3/h
Min. flow rate
6 m3/h
Max. head
420 m
Min. head
5 m
Mains frequency
50 Hz,
60 Hz
Mains voltage
230 V,
380 V,
400 V,
415 V,
460 V,
500 V,
690 V,
1000 V
Casing material
1.4404/AISI 316L,
1.4301/AISI 304
Nominal pressure
PN 63
Max. allowed working pressure
60 bar
Suction behaviour
Non-self-priming
Maximum allowable fluid temperature
50 °C
Minimum allowable fluid temperature
2 °C