Movitec VCI Vertical shaft submersible pump

Vertical shaft submersible pump Movitec VCI

Multistage vertical high-pressure immersion pump for installation on tanks or platforms.
See all documents and downloads

Main Applications

  • Machine tools
  • Industrial washing machines
  • Condensate transport

Technical Data

Max. flow rate
26.3 m3/h
Max. head
249 m
Max. allowed working pressure
25 bar
Maximum allowable fluid temperature
120 °C

Material number list – Movitec VCI

154 products
Material number
Price
MOVITECVCI02/02-02AA14CS071A5OWWithout400V2PC0PC2900Code 140.94AThree-phase currentInternal-thread connection15.6 kg48239986
Loading...
MOVITECVCI02/02-02AA14CS071A6OWIE3 (Premium)400V2PC0PC3500Code 140.89AThree-phase currentInternal-thread connection15.6 kg48240046
Loading...
MOVITECVCI02/03-03AA14CS071A5OWWithout400V3PC0PC2900Code 140.94AThree-phase currentInternal-thread connection15.9 kg48239987
Loading...
MOVITECVCI02/03-03AA14CS071A6OWIE3 (Premium)400V3PC0PC3500Code 140.89AThree-phase currentInternal-thread connection15.9 kg48240047
Loading...
MOVITECVCI02/04-04AA14CS071A5OWWithout400V4PC0PC2900Code 140.94AThree-phase currentInternal-thread connection16.2 kg48239988
Loading...

Benefits

  • Top quality pump thanks to advanced high-precision production technology and durable high-grade materials
  • Excellent reliability, enabled by compact, easy-to-replace cartridge seal and automatic return of small amounts of leakage into the tank
  • An energy-saving, state-of-the-art pump solution characterised by high efficiency levels, optimum flow passage, the use of high-efficiency motors, and precision engineering of all hydraulic components

Technical Data

Function
Pump
Connection type
Internal-thread connection
Drive concept
With electric actuator
Max. flow rate
26.3 m3/h
Min. flow rate
0.2 m3/h
Max. head
249 m
Min. head
0.1 m
Mains frequency
50 Hz,
60 Hz
Mains voltage
230 V,
400 V,
460 V
Casing material
1.4301
Nominal pressure
PN 25
Max. allowed working pressure
25 bar
Suction behaviour
Non-self-priming
Maximum allowable fluid temperature
120 °C
Minimum allowable fluid temperature
-10 °C