4ESD Pump-specific cartridge mechanical seal

Pump-specific cartridge mechanical seal 4ESD

For the Etanorm-R pump type series. Double, balanced cartridge seal, stationary (inboard) and dynamic (outboard) design.

Main Applications

  • Drinking water
  • Service water
  • Hot water

Technical Data

Cartridge seal
Yes
Design
Stationary
Balancing
Balanced mechanical seal
Sealing type
Double
Maximum allowable fluid temperature
140 °C

Your KSB contact: We’re here to support you

Do you need any assistance finding the right material number?
We’ll soon provide a list so you can directly place your purchase order.
Meanwhile please contact our support:

Tel: + 46 31 7202495


Your KSB contact : We’re here to support you

Benefits

  • Inboard seal in stationary design, outboard seal in dynamic design. The double mechanical seal's cartridge can be operated with either unpressurised buffer fluid or pressurised barrier fluid.
  • The springs are located outside the fluid handled.
  • G 1/4" barrier fluid inlet, outlet and drain connections

Technical Data

Maximum allowable axial movement
1.5 mm
Minimum allowable axial movement
-1.5 mm
Component type series
KSB Etanorm-R [B]
Cartridge seal
Yes
Maximum allowable dynamic pressure
25 bar
Design
Stationary
Balancing
Balanced mechanical seal
Sealing type
Double
Mtrl metallic compon.mech.seal
1.4571
Mtrl mech.seal spring
1.4571
Mtrl Secondary seal outboard
FKM,
EPDM,
K/M1 [FFKM/FKM, DOUBLE PTFE WRAPPED (FDA)]
Mtrl Secondary seal inboard
FKM,
EPDM,
K/M1 [FFKM/FKM, DOUBLE PTFE WRAPPED (FDA)]
Mtrl Mating ring outboard
B [CARBON, RESIN-IMPREGNATED]
Mtrl Mating ring inboard
Q1 [SIC, DRUCKLOS GESINTERT]
Mtrl Primary ring outboard
1.4122
Mtrl Primary ring inboard
Q1 [SIC, DRUCKLOS GESINTERT]
Direction of rotation
Bi-directional
Maximum allowable sliding velocity
16 m/s
Spring design
Multiple springs
Maximum allowable static pressure
37.5 bar
Maximum allowable fluid temperature
140 °C
Minimum allowable fluid temperature
-40 °C

Sectional Drawings

;