KWP Dry-installed pump

Dry-installed pump KWP

Horizontal radially split volute casing pump in back pull-out design, single-stage, single-entry, available with various impeller types: closed multi-channel impeller, open multi-vane impeller and vortex impeller. ATEX-compliant version available.
See all documents and downloads

Main Applications

  • Paper industry / pulp industry
  • Sugar industry
  • Food industry / beverage industry
  • Fossil-fuelled power stations

Technical Data

Max. flow rate
15000 m3/h
Max. head
140 m
Max. allowed working pressure
10 bar
Maximum allowable fluid temperature
140 °C

Your KSB contact: We’re here to support you

Do you need any assistance finding the right material number?
We’ll soon provide a list so you can directly place your purchase order.
Meanwhile please contact our support:

Your KSB contact : We’re here to support you

Benefits

  • Easy to service thanks to back pull-out design
  • Safe design: all pressure-retaining components cast with extra corrosion/wear allowance.
  • Standard pump with suction-side wear plate in wear-resistant diagonal gap design

Certificates

  • K07A_320572939-1_1
    Certified quality management to ISO 9001
    All countries

Technical Data

Function
Pump
Connection type
Flange
Drive concept
With electric actuator
Max. flow rate
15000 m3/h
Min. flow rate
4 m3/h
Max. head
140 m
Min. head
1 m
Mains frequency
50 Hz,
60 Hz
Mains voltage
400 V,
460 V,
1000 V
Casing material
EN-GJL-250,
NORIHARD NH153,
NORIDUR 1.4593,
NORICLOR1.4573,
EN-GJS-400-18-LT-POLYSIC
Nominal pressure
PN 10,
PN 16
Max. allowed working pressure
10 bar
Suction behaviour
Non-self-priming
Maximum allowable fluid temperature
140 °C
Minimum allowable fluid temperature
-40 °C

Sectional Drawings