Main Applications
- Waste water disposal
- Drainage of buildings, drainage of premises
- Redevelopment of premises
- Pumped drainage
Technical Data
- Max. flow rate
- 40 m3/h
- Max. head
- 49 m
- Maximum allowable fluid temperature
- 40 °C
Material number list – CK 800 Pump Station/CK 1000 Pump Station
49 productsMaterial number | Price | |||||||
---|---|---|---|---|---|---|---|---|
PUMPENSCHACHT CK 800 D | KSB CK-Pumpstation [A] | 80 kg | 19074285 | Loading... | ||||
PUMPENSCHACHT CK 800 E | KSB CK-Pumpstation [A] | 70 kg | 19074284 | Loading... | ||||
PUMPSTATION CK 800 D NS 32-1 EX | KSB CK-Pumpstation [A] | 2PC | KSB Amarex N [A] | KSB LevelControl Basic 2 [A] | 237 kg | 29130851 | Loading... | |
PUMPSTATION CK 800 D NS 50-1 EX | KSB CK-Pumpstation [A] | 2PC | KSB Amarex N [A] | KSB LevelControl Basic 2 [A] | 257 kg | 29130853 | Loading... | |
PUMPSTATION CK 800 D NS 50-2 EX | KSB CK-Pumpstation [A] | 2PC | KSB Amarex N [A] | KSB LevelControl Basic 2 [A] | 257 kg | 29130855 | Loading... |
Benefits
- Low weight pump station, ready to connect, minimal installation work
- Installation depths of up to 2700 mm, with anti-lift protection
- Variable pipe connections
Certificates
- Europe
Technical Data
- Connection type
- External-thread connection,
Pipe/hose connection - Drive concept
- With electric actuator
- Max. flow rate
- 40 m3/h
- Min. flow rate
- 0.1 m3/h
- Max. head
- 49 m
- Min. head
- 1 m
- Mains frequency
- 50 Hz
- Mains voltage
- 400 V
- Suction behaviour
- Non-self-priming
- Maximum allowable fluid temperature
- 40 °C
- Minimum allowable fluid temperature
- 0 °C