Amarex NS Submersible motor pump

Submersible motor pump Amarex NS

Vertical single-stage submersible motor pump for wet installation, with cutter (S), stationary or transportable version. Amarex N pumps are floodable, single-stage, single-entry close-coupled pump sets which are not self-priming. ATEX-compliant version available.
See all documents and downloads

Main Applications

  • Waste water management
  • Drainage systems
  • Waste water treatment plants
  • Sludge disposal

Technical Data

Max. flow rate
190 m3/h
Max. head
49 m
Max. allowed working pressure
16 bar
Maximum allowable fluid temperature
40 °C

Material number list – Amarex NS

36 products
Material number
Price
Amarex N S 32-160/02ULG-16032-160160mmwithout50Hz400V1.5kW9.4m3/h16.4m29 kg39190481
Loading...
Amarex N S 32-160/02YLG-16032-160160mmEEx d II50Hz400V1.5kW9.4m3/h16.4m29 kg39100380
Loading...
Amarex N S 50-170/012YLG-100 230V FM50-170100mmEEx d II60Hz230V1.9kW14.5m3/h9.9m45 kg39190446
Loading...
Amarex N S 50-170/012YLG-100 460V FM50-170100mmEEx d II60Hz460V1.9kW14.5m3/h9.9m45 kg39190447
Loading...
Amarex N S 50-170/012YLG-110 230V FM50-170110mmEEx d II60Hz230V1.9kW16.5m3/h12.6m45 kg39190448
Loading...

Benefits

  • Easy and fast installation/removal with polarised, absolutely watertight cable entry and KSB plug-type connection ensuring correct installation
  • Motor absolutely watertight, also in the event of damage to the cable sheath and core insulation, with individually stripped, tinned and resin-sealed conductors
  • High operating reliability with optimum motor selection for duty type S1, thermal class F, explosion-proof variant in "ATEX T4, FM/CSA Ex Class I, Division 1, Groups C & D, T4"

Technical Data

Function
Pump
Connection type
Flange
Drive concept
With electric actuator
Max. flow rate
190 m3/h
Min. flow rate
0.1 m3/h
Max. head
49 m
Min. head
0.1 m
Mains frequency
50 Hz,
60 Hz
Mains voltage
400 V,
460 V,
3000 V
Casing material
EN-GJL-250
Nominal pressure
PN 16
Max. allowed working pressure
16 bar
Suction behaviour
Non-self-priming
Maximum allowable fluid temperature
40 °C
Minimum allowable fluid temperature
0 °C

Characteristic curves

Sectional Drawings