Main Applications
- Pumping boiler feed water and condensate in power stations and industrial plants
- Generation of pressurised water for descaling units
Technical Data
- Max. flow rate
- 1278 m3/h
- Max. head
- 4000 m
- Max. allowed working pressure
- 400 bar
- Maximum allowable fluid temperature
- 200 °C
Benefits
- High operating reliability:
- For balancing by double drum: residual axial thrust absorbed by pivoted segmental thrust bearing
- Optimised casing design regarding the distribution of forces
Technical Data
- Function
- Pump
- Connection type
- Flange,
Butt weld ends - Drive concept
- With electric actuator,
Turbine - Max. flow rate
- 1278 m3/h
- Min. flow rate
- 0.1 m3/h
- Max. head
- 4000 m
- Min. head
- 0.1 m
- Mains frequency
- 50 Hz,
60 Hz - Mains voltage
- 400 V,
415 V,
440 V,
460 V,
480 V,
500 V,
525 V,
575 V,
600 V,
660 V,
690 V,
760 V,
830 V,
1000 V,
3000 V,
4160 V,
5000 V,
5500 V,
6000 V,
6600 V,
6900 V,
11000 V - Nominal pressure
- PN 160,
PN 250,
PN 320,
PN 400 - Max. allowed working pressure
- 400 bar
- Suction behaviour
- Non-self-priming
- Maximum allowable fluid temperature
- 200 °C
- Minimum allowable fluid temperature
- 2 °C