Type Series
(107 results)4EB
For the Etanorm-R/Etaline-R pump type series. Single balanced cartridge seal in stationary design. Tailored to the pump's seal installation space and requirements. The seal design facilitates installation without adjusting dimensions and ensures optimal pre-loading.
4EDBM6S/4EDBM6Q
Single mechanical seals to API 682, 4th edition. Single balanced cartridge seal, dynamic design.
4EDBM6T/4EDBM6D
Double mechanical seal to API 682, 4th edition. Balanced cartridge seal, Arrangements 2 and 3, dynamic design.
4EDCB8S
Single mechanical seal to API 682, 4th edition, Category 1, for the MegaCPK pump type series. Balanced cartridge seal, dynamic design.
4EDCB8T/4EDCB8D
Double mechanical seal to API 682, 4th edition, Category 1, for the MegaCPK pump type series. Balanced cartridge seal, Arrangements 2 and 3, dynamic design.
4EDTMP
For the RPH pump type series. Single cartridge seal, dynamic design. Specially developed for hot water applications. The seal comes with a floating throttling bush as standard for use with a gas or steam quench.
4EDTR6HS/4EDTR6HQ
Single metal-bellows mechanical seals to API 682, 4th edition. Balanced cartridge seal, Arrangement 1.
4EDTR6HT/4EDTR6HD
Double metal-bellows mechanical seal to API 682, 4th edition. Balanced cartridge seal, Arrangements 2 and 3.
4ES
For the Etanorm-R pump type series. Single cartridge seal in stationary design. The large springs are located outside the fluid handled and thus protected from contamination.
4ESD
For the Etanorm-R pump type series. Double, balanced cartridge seal, stationary (inboard) and dynamic (outboard) design.
4EYS
For the Etanorm SYT/Etabloc SYT/Etaline SYT pump type series. Single, unbalanced component seal, dynamic design. Solid primary rings designed to maintain an optimum lubricating film between the seal faces also at high pressures and temperatures. 4EYT variant in tandem arrangement also for use as a double mechanical seal.
4HLQ
For the HPK-L pump type series. Single, unbalanced component seal, dynamic design. Used in combination with KSB's 4HL single mechanical seal.
4K Cartridge
For the KWP pump type series. Single balanced cartridge seal in stationary design. With connection option for periodic flushing.
4KST
For the HPH/RPH-HW pump type series. Single, balanced component seal, stationary design. Optimised for operating conditions with extremely high pressures.
4MC
For the Movitec pump type series. Single, balanced cartridge seal designed for installation in vertical pumps for applications with high pressures and speeds.
4OMQ
For the Omega pump type series. Double, unbalanced cartridge seal, dynamic design. Especially designed for applications with negative suction pressure.
4Spider
For KSB's submersible motors. Single balanced cartridge seal in stationary design. Easy installation and removal also under difficult operating conditions.
4STK
For the Amarex KRT pump type series. Double, balanced cartridge mechanical seal, stationary design. An integrated impeller ensures the best possible circulation of the cooling liquid.
4UM
For KSB's submersible motors. Single balanced cartridge seal in stationary design. Easy installation and removal also under difficult operating conditions.
5HG-BM3
For the HG pump type series. Single, balanced component seal, dynamic design. The seal offers excellent adaptation options and ensures reliable long-term operation of the pump.
5HGTC
For the HG pump type series. Single balanced cartridge seal in stationary design. The shrink disc ensures reliable torque transmission to the mechanical seal.
5KSTRHMD
For the MegaCPK pump type series. Double, balanced cartridge seal with rotating metal bellows. Especially suitable for extreme temperature ranges.
5KSTSMA
For the MegaCPK pump type series. Single balanced component seal with rotating metal bellows.
AMTRONIC U
On/off control of pneumatic quarter-turn actuators and open/closed position signalling. Mounts directly on ACTAIR EVO / DYNACTAIR EVO actuators with a universal baseplate, providing a rugged, compact and integrated solution. Its integrated directional control valve eliminates the need for any pneumatic lines between AMTRONIC U and the actuator. The actuating time of the actuator can be set via AMTRONIC U's air flow reducer. AMTRONIC U can be connected to Profibus DP or AS-i field buses. AMTRONIC U has been specially developed to reduce control unit cabling. Connection via field bus enables both power supply and control information exchange with the process control system.
BOA-MP
Measuring pipe with integrated ultrasonic sensors for identifying flow direction and measuring volume flow rate and temperature, sensors not in contact with fluid handled, constant measuring accuracy independent of minimum differential pressures. Stationary monitoring by means of BOATRONIC 100 MOD (24 V AC/DC, Modbus) of flow direction and volume flow rate; optional measurement of supply and return temperature, thermal output and quantity of heat. Mobile measurement of flow direction, volume flow rate and temperature using the BOATRONIC 100 measuring computer (rechargeable battery powered).
BOA-Systronic ePIC
Smart and pressure-independent measurement and control valve (2-way energy valve) for monitoring and controlling flow direction, volume flow rate, supply and return temperature, thermal output and quantity of heat as well as automating the hydraulic balancing process. With integrated ultrasonic flow rate measurement and temperature sensor not in contact with the fluid handled; includes: 2 additional Pt1000 temperature sensors for measuring the supply and return temperature, integrated basic control functions (position, flow rate, temperature, thermal output), integrated process optimisation functions (delta-T management and limitation features). Also available with electrostatic plastic coating (EKB) and DVGW-certified for drinking water.
BOATRONIC 100/BOATRONIC 100 MOD
Ultrasonic measuring computer for use with balancing, measurement and shut-off valves, and measuring pipes; commissioning, operation and display via the KSB FlowManager app and the KSB ServiceTool; direct measurement without having to enter valve travel; fluid-specific data for water and water/glycol mixtures available for direct selection. BOATRONIC 100: Measuring computer for mobile measurement of flow direction, volume flow rate and temperature, compatible with BOA-Control / BOA-Control IMS balancing and shut-off valves and with BOA-MP measuring pipe; with rechargeable batteries 6x1.2 V AA Mignon (not included in the scope of supply); includes magnetically attaching sensor set (for BOA-Control DN 15-200). BOATRONIC 100 MOD: Measuring computer for monitoring and permanently measuring flow direction, volume flow rate, supply and return temperature, thermal output and quantity of heat using ultrasound; compatible with BOA-Control IMS balancing and shut-off valve and with BOA-MP measuring pipe; communication via 2 analog signals (0/4-20 mA / 0/2-10 V / 0-5 V) and Modbus RTU, supply voltage 24V AC/DC.
CHTRa
Horizontal axially split single-entry multistage between-bearings volute casing pump with single casing and back-to-back impeller arrangement to API 610 (ISO 13709), type BB3. First stage optionally available in double-entry design for low NPSH requirements. ATEX-compliant version available.
ECOLINE GLC 150-600
Globe valve to ANSI/ASME with flanged ends, cast steel A216 WCB, Trim 8 (Stellite/13 % chrome steel) for Class 150/300/600, Trim 5 (Stellite/Stellite) for Class 600, with bolted bonnet, outside screw and yoke, graphite gland packing, stainless steel/graphite gaskets.
ECOLINE GTB 800
Gate valve to ANSI/ASME with threaded sockets (NPT) or socket weld ends (SW), cast steel/stainless steel body, trim and bellows made of stainless steel, bolted bonnet, outside screw and yoke, sealed by graphite gland packing and metal bellows, stainless steel/graphite gaskets.
ETA C/D
Horizontal single- or two-stage centrifugal pump with volute casing. Casing flanged to the support bracket. Sizes 100-50/2 and 125-50/2 have two stages. Radial overhung impeller, with balancing holes for hydraulic balancing. Replaceable wear rings and shaft protecting sleeves.
Etanorm SYT
Horizontal volute casing pump in back pull-out design, single-stage, with ratings and dimensions to EN 733, radially split volute casing with integrally cast pump feet, replaceable casing wear rings, closed radial impeller with multiply curved vanes, single mechanical seal to EN 12756, double mechanical seal to EN 12756, drive-end bearings: rolling element bearings, pump-end bearings: plain bearings, with magnetless KSB SuPremE motor (exception: motor sizes 0.55 kW / 0.75 kW with 1500 rpm are designed with permanent magnets) of efficiency class IE4/IE5 and PumpDrive variable speed system; ATEX-compliant version available.
KSB Flood Fighter L
Complete floodwater drainage set, comprising an AmaDrainer 507 pump including pre-assembled hose adapter with Storz C coupling and a drainage hose. The fully floodable, vertically installed, single-stage submersible motor pump has got an extra long power cable (20 m), is designed with an IP68-rated enclosure, and is suitable for a maximum immersion depth of 7 m. The supplied 15 m long drainage hose can be extended. A robust plastic crate and safety gloves are also included in the scope of supply. A power generator is available on request.
KTS52
KTS52 – thermosyphon system to API 682,4th edition. For double mechanical seals (Arrangement 2). The buffer fluid pressure is lower than the pressure in the pump’s seal chamber. The system supplies the space between the seals with a clean buffer fluid.
KTS53A
KTS52 – thermosyphon system to API 682,4th edition. For double mechanical seals (Arrangement 3). The barrier fluid pressure is higher than the pressure in the pump’s seal chamber. The system supplies the space between the seals with a clean barrier fluid.
KTS53B
Closed barrier fluid system to API 682, 4th edition. For double mechanical seals (Arrangement 3). The barrier fluid pressure is higher than the pressure in the pump’s seal chamber. The barrier fluid pressure is generated by a pre-loaded bladder accumulator. Equipped with water cooler or air cooler.
KWT23
Heat exchanger to API 682, 4th edition For single or double mechanical seals. Used for high-temperature hot water, boiler feed water and many hydrocarbons. The heat exchanger cools the product upstream of the inboard mechanical seal.
LCV
Robust vertical shaft submersible pump in cantilever design with suction from the bottom and bearings arranged outside of the fluid handled. Design with open and closed impeller for best efficiency and maximum free passage. Wear parts of wetted pump components (casing, impeller, suction cover / liner) made of white cast iron with a high chromium content and therefore very wear-resistant. The maximum permissible working pressures are between 7 and 11 bar, depending on the pump size. Perfectly suited for transporting fluids containing hardly to slightly abrasive solids. Ideal for sludges, classes 1 to 2.
MIL 10000
The top- and bottom-guided double-ported control valve is characterised by a high permissible pressure drop across the valve. The high flow capacity typical of this design is attained with low pressure recovery. Bi-directional flow is permitted; wide flow passage, suitable for viscous fluids.
RVT
Vertical multistage barrel pull-out pump with double-entry suction impeller and forged distributor casing.
SISTO-C
Diaphragm valve with butt weld ends or clamps; in straight-way, Y or T pattern, or as a multi-port valve; shut-off and sealing to atmosphere by confined and supported diaphragm. No dead volumes, suitable for sterilisation, SIP/CIP-compliant design, position indicator. All moving parts are separated from the fluid by the diaphragm. Maintenance-free.
SISTO-LAP
Piston actuator in heavy-duty design for mounting on valves with a linear stem movement (globe valves, diaphragm valves and gate valves). Actuator flange to DIN/ISO 5210. Available in single-acting spring-to-close or spring-to-open design, or double-acting air-to-open/air-to-close design; suitable for mounting limit switches or positioners to suit customer requirements.
SISTO-SK-i
Intelligent actual-position feedback unit for linear valves, clear visual indication of valve position by colour-coded high-visibility LEDs, user-friendly setting of limit positions by automatic initialisation in situ or via the process control system; continuously records valve travel and comprises a microcontroller-based analysing unit; valve position is signalled visually by the device’s high-visibility LEDs and electrically via digital outputs; connected via an M12 plug connector, ready for operation as soon as initialisation is complete.
SMARTRONIC U MA
Digital electro-pneumatic positioner powered via the 4-20 mA signal. Mounts on ACTAIR EVO / DYNACTAIR EVO actuators with direct compressed air supply, or on any type of quarter-turn actuator with VDI/VDE 3845 interface and linear actuators with NAMUR interface. SMARTRONIC U MA reduces investment, commissioning and operating costs as no air is consumed in idle state.
UNITAS Q/UNITAS T
Single balanced cartridge seal in stationary design. Designed for universal use in the seal installation spaces of various pump manufacturers. Pump-specific seal variants available with centring diameter on the seal cover, ensuring an optimum radial installation position of the mechanical seal in KSB pump type series.
UNITAS S
Single balanced cartridge seal in stationary design. Designed for universal use in the seal installation spaces of various pump manufacturers. Pump-specific seal variants available with centring diameter on the seal cover, ensuring an optimum radial installation position of the mechanical seal in KSB pump type series.
WKB
Vertically suspended, single-casing, lineshaft, diffuser-type pump with integral thrust bearings and discharge through column pipe in accordance with API 610 / ISO 13709 (VS1). Available in single-stage and multistage configurations and with either single or double suction first-stage impeller.
ZW
Double-entry vertical shaft submersible pump in cantilever design with bearings arranged outside of the fluid handled. Double-entry pump design enables handling of fluids with a high solids content without leaving any residues. Wear parts of wetted pump components (casing, impeller, shaft-end plate / liner) made of white cast iron with a high chromium content and therefore very wear-resistant. Perfectly suited for transporting fluids containing hardly to slightly abrasive solids. Ideal for sludges, classes 1 to 2.