Main Applications
- Feed water in power stations
- Boiler feed applications
- Condensate transport
- Pressurised water generation for presses, bark peeling systems, descaling systems and snow-making systems
Technical Data
- Maximum flow rate TSG
- 1440 m3/h
- Maximum head TSG
- 4200 m
- Max allow ds work.pressure TSG
- 420 bar
- Max allowed fluid temp TSG
- 200 °C
Benefits
- High operating reliability by axial thrust balancing via balance disc and adaptation of pump casing to rotor deflection line
- Extraction of a partial flow or several partial flows of feed water for use elsewhere in the power station
- Maintenance-friendly design with easy-to-replace wear parts (bearings, sealing elements, balancing devices) and metal-to-metal sealing of casing
Technical Data
- Component function
- Pump
- Connection type Inlet
- Flange
- Drive concept
- With electric actuator,
Turbine - Maximum flow rate TSG
- 1440 m3/h
- Minimum flow rate TSG
- 7.2 m3/h
- Maximum head TSG
- 4200 m
- Minimum head TSG
- 140 m
- Mains frequency
- 50 Hz,
60 Hz - Mains voltage
- 400 V,
460 V,
500 V,
690 V,
1000 V,
3000 V,
4160 V,
5000 V,
5500 V,
6000 V,
6600 V,
11000 V - Mtrl Hydraulic casing
- 1.4006+QT650
- Nominal pressure Outlet
- PN 420
- Max allow ds work.pressure TSG
- 420 bar
- Suction behaviour
- Non-self-priming
- Max allowed fluid temp TSG
- 200 °C
- Min allowed fluid temp TSG
- 0 °C