Main Applications
- Nuclear power stations
Technical Data
- Nominal pressure
- PN 210, Special
- Max. nominal size
- DN 300
- Maximum allowable fluid temperature
- 365 °C
Technical Data
- Function
- Prevent backflow
- Connection type
- Butt weld ends
- Casing material
- P280GH,
P250GH,
SA105,
1.4550,
Z6 CNNB 18-11,
SA182 GR F316L - Nominal pressure
- PN 210,
Special - Max. nominal size
- DN 300
- Min. nominal size
- DN 65
- Maximum allowable fluid temperature
- 365 °C
- Minimum allowable fluid temperature
- -29 °C