Main Applications
- Aggressive fluids
- Chemical industry (aggressive / other liquids)
- Gas applications
Technical Data
- Max. flow rate
- 260 m3/h
- Max. head
- 140 m
- Max. allowed working pressure
- 25 bar
- Maximum allowable fluid temperature
- 200 °C
Benefits
- Semi-open impeller with wear plate and external adjustment
- Easy maintenance due to back pull-out design
- Design with dry shaft, i.e. no contact between fluid handled and shaft
Technical Data
- Function
- Pump
- Connection type
- Flange
- Drive concept
- With electric actuator
- Max. flow rate
- 260 m3/h
- Min. flow rate
- 1.2 m3/h
- Max. head
- 140 m
- Min. head
- 6 m
- Mains frequency
- 50 Hz,
60 Hz - Mains voltage
- 415 V
- Casing material
- IS210 GR FG260,
A216 GR WCB,
A995 GR 1B,
A743 GR CF8,
A743 GR CF8M - Nominal pressure
- PN 25
- Max. allowed working pressure
- 25 bar
- Suction behaviour
- Non-self-priming
- Maximum allowable fluid temperature
- 200 °C
- Minimum allowable fluid temperature
- -70 °C