![AmaDS³ Solids separation system](https://acszigalen.cloudimg.io/v7/https%3A%2F%2Flive-commerce-proxy-e2e-sales.ksb.com%2Fmedias%2FA56A-Ama-DS3.png%3Fcontext%3DbWFzdGVyfGltYWdlc3wxMjQ3NjMwfGltYWdlL3BuZ3xhVzFoWjJWekwyaGxNQzlvTVdNdk9EZ3hORGN6T0RBM09UYzNOQzV3Ym1jfDA0NWU4ZjRiMzk0NDAwNTliMzQwMjg1NWM2YTgwYmJlZTQxYWVmZGI3ZmM4ZThlMTExYmMwZWQzYjEwZGY4ZDM?br_px=3213%2C3213&ci_url_encoded=1&tl_px=1512%2C1512&w=1000&force_format=webp&q=60)
Main Applications
- Waste water disposal
- Waste water transport
Technical Data
- Max. flow rate
- 800 m3/h
- Max. head
- 100 m
- Max. allowed working pressure
- 10 bar
- Maximum allowable fluid temperature
- 40 °C
Benefits
- An economical solution enabling the use of pumps with a smaller free passage as the water to be pumped has been mechanically treated.
- Reliable, dependable and non-clogging as the pump’s interior is protected from coarse solids.
- One of the pumps can be serviced while the system is running, provided that gate valves have been installed for shut-off, as all key components are fully redundant.
Technical Data
- Connection type
- Flange
- Drive concept
- With electric actuator
- Max. flow rate
- 800 m3/h
- Min. flow rate
- 2 m3/h
- Max. head
- 100 m
- Min. head
- 1.5 m
- Mains frequency
- 50 Hz,
60 Hz - Mains voltage
- 400 V,
460 V - Casing material
- 1.4571,
1.4301 - Max. allowed working pressure
- 10 bar
- Suction behaviour
- Non-self-priming
- Maximum allowable fluid temperature
- 40 °C
- Minimum allowable fluid temperature
- 2 °C