![DeltaBasic Pressure booster system](https://acszigalen.cloudimg.io/v7/https%3A%2F%2Flive-commerce-proxy-e2e-sales.ksb.com%2Fmedias%2FDeltaBasicSVP-MVP-2023-1-.png%3Fcontext%3DbWFzdGVyfGltYWdlc3wxMjk0Njk0fGltYWdlL3BuZ3xhRFEwTDJoaVpDODVNREl3TXprd016QTVPVEU0TDBSbGJIUmhRbUZ6YVdOVFZsQmZUVlpRWHpJd01qTmJNVjB1Y0c1bnwxZjNiMzUwNWQ2MzAxYWI5YzY3YzRkOTA2NzBlNWMyY2QxYzAwODhmZWY5MWUxMWUzNDAxODU2YTQzMzhjYzU1?tl_px=1512,1512&br_px=3213,3213&w=1000&force_format=jpeg&ci_url_encoded=1&optipress=3)
Main Applications
- Pressure boosting
Technical Data
- Max. flow rate
- 65.4 m3/h
- Max. head
- 134 m
- Max. allowed working pressure
- 16 bar
- Maximum allowable fluid temperature
- 60 °C
Benefits
- Energy-efficient operation and constant pressure ensured by speed control of all pumps.
- Suitable for drinking water; manufactured under stringent hygienic conditions
- Easy and fast commissioning of ready-to-connect, pre-assembled and tested system
Certificates
- Approved in accordance with the UK drinking water regulationUnited Kingdom
- Approved in accordance with the French drinking water regulationFrance
- Approved in accordance with the German drinking water regulationGermany
Technical Data
- Connection type
- External-thread connection,
Flange - Drive concept
- With electric actuator
- Max. flow rate
- 65.4 m3/h
- Min. flow rate
- 0.2 m3/h
- Max. head
- 134 m
- Min. head
- 13 m
- Function Intg software Ctrl ut
- Control
- Mains frequency
- 50 Hz
- Mains voltage
- 400 V
- Casing material
- GX5CRNI19-10
- Nominal pressure
- PN 16
- Max. allowed working pressure
- 16 bar
- Suction behaviour
- Non-self-priming
- Maximum allowable fluid temperature
- 60 °C
- Minimum allowable fluid temperature
- 0 °C