Main Applications
- Biogas plants
- Chemical industry
- Fossil-fuelled power stations
- Oil and gas
Technical Data
- Nominal pressure
- CL 300, CL 400, CL 600
- Max. nominal size
- DN 100
- Maximum allowable fluid temperature
- 280 °C
Benefits
- Safe use: fire-safe design to ATEX.
- Anti-static design prevents electrostatic charging during operation
Technical Data
- Function
- Shut off/control flow
- Connection type
- Internal-thread connection,
Butt weld ends,
Socket weld ends - Design concept Drive
- Lever,
With pneumatic actuator - Casing material
- A351 GR CF3M,
A216 GR WCB - Nominal pressure
- CL 300,
CL 400,
CL 600 - Max. nominal size
- DN 100
- Min. nominal size
- DN 10
- Maximum allowable fluid temperature
- 280 °C
- Minimum allowable fluid temperature
- -196 °C