Vitaprime Dry-installed pump

Dry-installed pump Vitaprime

Service-friendly close-coupled side-channel pump (self-priming) with magnetless KSB SuPremE motor (exception: motor sizes 0.55 kW / 0.75 kW with 1500 rpm are designed with permanent magnets) of efficiency class IE4/IE5 and PumpDrive variable speed system. All wetted components are made of 1.4404/1.4409 (AISI 316L/CF3M) stainless steel. Hygienic design for the highest cleanability requirements (CIP/SIP-compatible). All materials comply with FDA standards and EN 1935/2004. Trolley available among other accessories. ATEX-compliant version available.
See all documents and downloads

Main Applications

  • Food industry / beverage industry
  • Chemical industry/Fine chemicals
  • Pharmaceutical industry
  • Further industrial applications

Technical Data

Max. flow rate
60 m3/h
Max. head
65 m
Max. allowed working pressure
10 bar
Maximum allowable fluid temperature
100 °C

Material number list – Vitaprime

6 products
Material number
Price
VP 40-146 0154MB T82MECCO O41 kg48256748
Loading...
VP 50-164 0304MB T82MECCO O61 kg48256749
Loading...
VP 60-200 0554MB T82MECCO O103 kg48256750
Loading...
VP 65-200 0754MB T82MECCO O104 kg48256751
Loading...
VP 80-240-111104MB T82MECCO O146 kg48256752
Loading...

Benefits

  • Side channel pump for good and fast self-priming and for transporting fluids containing gas
  • Easy to clean with very little dead volume and excellent flushing capability
  • Service-friendly design, easy and fast to dismantle

Certificates

  • V07A_976471307-1_2
    Certified quality management to ISO 9001
    All countries
  • V07A_976471307-2_2
    Elastomers certified to FDA, 3A, USP Class VI
    All countries

Technical Data

Function
Pump
Connection type
Clamped connection,
External-thread connection,
Flange
Drive concept
With electric actuator
Max. flow rate
60 m3/h
Min. flow rate
1 m3/h
Max. head
65 m
Min. head
3.5 m
Mains frequency
50 Hz,
60 Hz
Mains voltage
400 V,
460 V
Casing material
GX2CRNIMO19-11-2
Nominal pressure
PN 10
Max. allowed working pressure
10 bar
Suction behaviour
Self-priming
Maximum allowable fluid temperature
100 °C
Minimum allowable fluid temperature
2 °C

Sectional Drawings

Selection charts