4STQ Pump-specific cartridge mechanical seal

Pump-specific cartridge mechanical seal 4STQ

For the Sewatec/Sewabloc and Amarex KRT pump type series. Double, balanced cartridge seal, stationary design. Springs located outside the fluid handled in the oil reservoir.
See all documents and downloads

Main Applications

  • Untreated sewage

Technical Data

Cartridge seal
Yes
Design
Stationary
Balancing
Balanced mechanical seal
Sealing type
Double
Maximum allowable fluid temperature
100 °C

Your KSB contact: We’re here to support you

Do you need any assistance finding the right material number?
We’ll soon provide a list so you can directly place your purchase order.
Meanwhile please contact our support:

Čechy     241 090 213
Morava  585 208 518


Your KSB contact : We’re here to support you

Benefits

  • Double mechanical seal in tandem arrangement, can be installed as one unit, bi-directional and balanced.
  • Stationary design, springs located outside the fluid handled in the oil reservoir The springs are insensitive to contamination and provide uniform surface pressure across the seal faces, thus ensuring a long service life.
  • Tailored to the seal installation space and requirements of the pump.

Technical Data

Maximum allowable axial movement
2 mm
Minimum allowable axial movement
-2 mm
Component type series
KSB Amarex KRT [B],
KSB Sewabloc [B],
KSB Sewatec [B]
Cartridge seal
Yes
Maximum allowable dynamic pressure
16 bar
Design
Stationary
Balancing
Balanced mechanical seal
Sealing type
Double
Mtrl metallic compon.mech.seal
1.4122
Mtrl mech.seal spring
1.4571,
2.4610
Mtrl Secondary seal outboard
FKM
Mtrl Secondary seal inboard
FKM
Mtrl Mating ring outboard
Q1 [SIC, DRUCKLOS GESINTERT],
U2 [TUNGSTEN CARBIDE, NI-BINDER]
Mtrl Mating ring inboard
Q1 [SIC, DRUCKLOS GESINTERT]
Mtrl Primary ring outboard
Q1 [SIC, DRUCKLOS GESINTERT]
Mtrl Primary ring inboard
Q1 [SIC, DRUCKLOS GESINTERT]
Direction of rotation
Bi-directional
Maximum allowable sliding velocity
10 m/s
Spring design
Multiple springs
Maximum allowable static pressure
20 bar
Maximum allowable fluid temperature
100 °C
Minimum allowable fluid temperature
-40 °C

Sectional Drawings

;