WKTA Barrel pull-out pump

Barrel pull-out pump WKTA

Vertical can-type ring-section pump, radial and mixed flow hydraulic system, single-entry and multi-entry impellers
See all documents and downloads

Main Applications

  • Pumping condensate in power stations and industrial plants

Technical Data

Max. flow rate
1800 m3/h
Max. head
340 m
Max. allowed working pressure
40 bar
Maximum allowable fluid temperature
100 °C

Your KSB contact: We're here to support you

Do you need any assistance finding the right material number?
We’ll soon provide a list so you can directly place your purchase order.
Meanwhile please contact our support:

Tel: + 46 31 7202495


Your KSB contact : We’re here to support you

Benefits

  • Optimum matching to customer requirements with a range of material variants
  • High operating reliability by casing wear rings with anti-seizure properties
  • Smooth running with low-wear, product-lubricated plain bearings

Technical Data

Function
Pump
Connection type
Flange
Drive concept
With electric actuator
Max. flow rate
1800 m3/h
Min. flow rate
310 m3/h
Max. head
340 m
Min. head
50 m
Mains frequency
50 Hz,
60 Hz
Mains voltage
400 V,
460 V
Casing material
GP240GH+QT KTA
Nominal pressure
PN 40
Max. allowed working pressure
40 bar
Suction behaviour
Non-self-priming
Maximum allowable fluid temperature
100 °C
Minimum allowable fluid temperature
2 °C