Main Applications
- Pumping neutral degreasing solutions and phosphating solutions
- Lubricating oil supply and sealing oil supply for turbines, generators, large compressors, large gear units
Technical Data
- Max. flow rate
- 740 m3/h
- Max. head
- 100 m
- Max. allowed working pressure
- 10 bar
- Maximum allowable fluid temperature
- 95 °C
Benefits
- Improved efficiency and NPSHreq by experimentally verified hydraulic design of impellers (vanes)
- Operating costs reduced by trimming the nominal impeller diameter to match the specified duty point
- Cover plate serves as tank cover and for mounting the pump.
Technical Data
- Function
- Pump
- Connection type
- Flange
- Drive concept
- With electric actuator
- Max. flow rate
- 740 m3/h
- Min. flow rate
- 1.5 m3/h
- Max. head
- 100 m
- Min. head
- 2 m
- Mains frequency
- 50 Hz,
60 Hz - Mains voltage
- 400 V,
460 V - Casing material
- EN-GJL-250/A48 CL 35B,
1.4408/A743CF8M - Nominal pressure
- PN 16
- Max. allowed working pressure
- 10 bar
- Suction behaviour
- Non-self-priming
- Maximum allowable fluid temperature
- 95 °C
- Minimum allowable fluid temperature
- -30 °C